Two instruments, two different physics
A GPR survey and an electromagnetic locator survey both look for buried services, but they detect different things, so neither replaces the other.
An electromagnetic locator (EML, often called a cable locator or CAT, from “cable avoidance tool”) is a receiver that picks up magnetic fields around buried conductors. In passive mode it listens for signals already there: the field around a power cable carrying current, or radio signals re-radiated by long metal pipes and cables. In active mode a signal generator (a “genny”) puts a known signal onto a pipe or cable, by direct connection, by clamp, or by induction from the surface, and the receiver traces it. A small transmitter called a sonde can also be pushed along a pipe or duct and followed from above.
Ground penetrating radar (GPR) sends short radar pulses into the ground and records the echoes that come back from anything with different electrical properties from the soil around it: a pipe, a cable, a duct, a void, the edge of an old trench. ASTM D6432, the American standard guide to surface GPR, describes radar frequencies from 10 to 3,000 MHz for this work. A buried pipe crossed at right angles appears as a curved echo; an operator joins those echoes from line to line into a route.
The difference that matters on site: the locator follows a signal, so it can tell you that this line is the one connected to that valve. The radar shows a contrast, so it can see things the locator cannot, but the UK Health and Safety Executive’s guidance HSG47 says plainly that radar alone “would not determine the precise nature of the service”.
What each one finds
The table sums up what the two main guidance documents, HSE’s HSG47 (2014) and The Survey Association’s client guide to PAS 128 (May 2025), say about common buried services. “Often” means it depends on ground, depth and congestion.
| Buried service | Locator, passive | Locator, active (signal generator or sonde) | GPR |
|---|---|---|---|
| Power cable carrying current | Yes | Yes | Often |
| Cable with little or no current (street lights by day, empty premises) | No | Yes, if the signal can be applied | Often |
| Low-voltage DC cable | Often not | Yes, may need access to earthing | Often |
| Metal water or gas pipe | Sometimes, by re-radiated radio | Yes, best with a direct connection | Often |
| Plastic water or gas pipe | No | Only with a tracer wire, a sonde inside, or markers | Often, if it contrasts with the soil |
| Cable inside a plastic duct | No, unless sheathed in metal | With a tracer rod in the duct | Yes, usually |
| Fibre laid straight in the ground | No | No | Unlikely |
| Concrete or clay sewer | No | With a sonde inside | Often, if not too deep |
| Old trench or backfill | No | No | Yes, often |
| Two services one above the other | Lower one may be missed | Better, but still hard | A metal upper service hides the lower |
| Service under reinforced concrete | Distorted readings | Distorted readings | Cannot see beneath the steel |
| Deep sewer | Beyond range | Sonde inside only | Beyond range |
Three notes from HSG47 explain most of the “no” answers. Locators, “with the possible exception of ground-probing radar”, do not detect plastic pipes unless a tracer wire, an inserted transmitter or a marker gives them a signal, and few plastic gas and water pipes have been laid with tracer wires. A tracer wire “may not be continuous” if it was damaged or badly laid. And where two services run close together, a locator may show them as one signal, missing the lower one.
How deep each one sees
Radar depth is set by the ground, not by the machine’s brochure. Radar energy is absorbed by electrically conductive ground. ASTM D6432 lists “high conductivity soils, sediments saturated with salt water or highly conductive fluids, and metal” as environments not suited to the method. The US Environmental Protection Agency goes further: “In environments with surficial layers of saturated clays or saline water, the DOI [depth of investigation] may be limited to centimeter scale”, while in dry sand and gravel it cites depths of up to 50 m. Between those extremes sits most real ground.
Frequency is the other control. The EPA notes a trade-off between resolution, which improves with higher frequency, and depth, which improves with lower frequency. A high-frequency antenna that shows a small pipe clearly near the surface will not see a deep sewer; a low-frequency one that reaches the sewer may miss the small pipe. Good surveys use the right antenna for the targets expected, and some use more than one.
For a site in Pakistan this has practical meaning. Land that has just been irrigated or flooded, ground after monsoon rain, saline patches and clay soils all reduce radar depth, sometimes sharply. The same site may give a useful radar picture in a dry month and very little after rain. A survey report should say how deep the radar actually reached in each part of the site, not how deep the equipment can reach in ideal ground.
Locator depth works differently. The receiver estimates depth from the shape of the magnetic field, which works when the field is clean and symmetrical. The Survey Association’s guide warns that nearby utilities and cables distort the field and lead to “unreliable depth measurements”. In a narrow lane where water, gas, power and telecom lines run side by side, locator depths need checking.
How accurate is GPR, and how accurate is the locator?
Across the ground, both instruments can place a line well when conditions are good. Depth is the weak point for both.
GPR does not measure depth directly. It measures the time an echo takes to come back, and converts that time to depth using the speed of the radar wave in the soil. That speed changes with moisture and soil type. If the surveyor assumes the wrong speed, every depth on the site is out in the same direction. A careful surveyor calibrates the speed on site, from a known target or a trial hole, and states how.
A locator’s depth depends on a clean field, as above, and on the signal being on the right line. When a signal bleeds onto a neighbouring pipe, the locator follows the wrong service with confidence.
PAS 128, the UK specification, turns this into a grade for each detected line, with stated position and depth tolerances, and grades a line found by the locator alone and not confirmed by radar no better than QL-B3. Rather than repeat those figures here, our guide to utility survey quality levels sets out the tolerance for each level and what it means for a pipe at 1.5 m depth.
Choose by the question you are asking
“GPR or locator?” is the wrong starting point. Start with the question the survey must answer, and the instruments follow.
| Your question | What answers it | Why |
|---|---|---|
| Is there a live cable where we are about to dig? | Locator, passive and active, then hand-dug trial hole | Live cables give a signal; a genny finds the quiet ones |
| Where does the plastic water main run? | GPR, the owner’s record, and a tracer wire or sonde if one exists | Plastic gives the locator nothing to follow |
| Is the ground clear for a borehole or test pit? | Both, at a close grid around the point, then hand-dig the start | A drill meets the ground blind |
| What is under this slab or floor? | High-frequency GPR, knowing it cannot see beneath the steel | Reinforcement blocks radar and distorts the locator |
| Map everything along a road we will widen | Both, on a planned grid, with chambers lifted and records compared | Each instrument covers the other’s blind spots |
| Exactly how deep is the gas main at the crossing? | Trial hole | Neither instrument proves depth; exposure does |
| Is this the line that feeds that building? | Locator with the signal applied at a known point | Only a signal can link a line to its source |
The pattern is consistent with every standard we have read: detection narrows the search; a trial hole confirms. HSG47 puts it simply: “Use trial holes to positively identify a service and its depth.”
What a good detection report says about the instruments
A detection survey report should let a reader judge how much to trust each line. Beyond the utility plan itself, ask for:
- The methods used in each area: passive locator, active locator with how the signal was applied, GPR, and any sonde or tracer work.
- The radar frequency or frequencies, and whether the data was reviewed in the office (post-processed) or only on screen in the field.
- How deep the radar reached in each part of the site, and the ground and weather conditions on the day.
- How GPR depths were calibrated: the wave speed used and where it was checked.
- Areas where neither instrument could see: under slabs, beside steel fences, in waterlogged ground, beyond depth.
- Records that were not confirmed: lines shown by the owners’ records that the instruments did not find.
- Ground marks: how lines were marked on site, and in what coordinates the plan is drawn, ideally the same as the topographic survey (see our guide to UTM zones and coordinate systems in Pakistan).
A report that lists every line with equal confidence and has no “not found” or “not surveyed” section has hidden the limits rather than removed them.
Red flags in a “GPR survey” quote
Some quotes sell radar as a complete answer. Watch for these:
- Radar only, no locator. Live and dead cables, and the link from a line to its source, need the locator. PAS 128 requires both for a detection survey.
- Locator only, no radar. Plastic pipes, ducts and old trenches go unseen.
- “All services located” or “100% detection”. The Survey Association’s guide says a well designed survey should detect around 80% to 95% of utilities and that 100% may not be possible.
- Depths with no method. Every depth should say whether it came from radar (with its calibration), the locator, or a trial hole.
- No trial holes anywhere on a job where excavation will run close to a main.
- No statement of ground conditions or achieved radar depth.
In Pakistan there is no national standard to point to, and we know of no call-before-you-dig service, so the brief has to carry these requirements; where records come from here is covered in our guide’s section on where QL-D comes from in Pakistan. Our underground utility survey combines records, surveyed surface features, electromagnetic location, ground penetrating radar and trial holes, and states on the plan how each line was found and where neither instrument could see. To scope a survey, send the site location, a plan of where you will dig or design, and any records you hold through our contact page.