GPR survey vs electromagnetic locator: what each finds, how deep, and when you need both

Published · 9 min read · RN Tech Associates · in Engineering surveys and utilities

Short answer

A GPR survey sends radar pulses into the ground and maps echoes from pipes, ducts and trenches, metal or plastic, but it cannot tell what it sees and may reach only centimetres in wet clay or saline ground. An electromagnetic locator traces metal pipes and cables through their signal, but misses plastic. Most utility surveys need both, plus trial holes.

GPR survey vs electromagnetic locator: what each finds, how deep, and when you need both

Key points

  • An electromagnetic locator finds metal pipes and cables. It does not find plastic pipes unless a tracer wire, sonde or marker was laid with them.
  • Ground penetrating radar can see plastic pipes, ducts and old trenches, but it cannot identify what it sees and cannot see beneath metal.
  • Radar depth depends on the ground. The US EPA notes it may be limited to centimetres in saturated clay or saline ground.
  • Passive locating misses cables carrying little or no current, and many DC cables. A signal generator finds far more.
  • Under PAS 128, a detection survey must use both instruments; a line found by the locator alone is graded no better than QL-B3.
  • Only a trial hole proves what a service is and how deep it lies.

Two instruments, two different physics

A GPR survey and an electromagnetic locator survey both look for buried services, but they detect different things, so neither replaces the other.

An electromagnetic locator (EML, often called a cable locator or CAT, from “cable avoidance tool”) is a receiver that picks up magnetic fields around buried conductors. In passive mode it listens for signals already there: the field around a power cable carrying current, or radio signals re-radiated by long metal pipes and cables. In active mode a signal generator (a “genny”) puts a known signal onto a pipe or cable, by direct connection, by clamp, or by induction from the surface, and the receiver traces it. A small transmitter called a sonde can also be pushed along a pipe or duct and followed from above.

Ground penetrating radar (GPR) sends short radar pulses into the ground and records the echoes that come back from anything with different electrical properties from the soil around it: a pipe, a cable, a duct, a void, the edge of an old trench. ASTM D6432, the American standard guide to surface GPR, describes radar frequencies from 10 to 3,000 MHz for this work. A buried pipe crossed at right angles appears as a curved echo; an operator joins those echoes from line to line into a route.

The difference that matters on site: the locator follows a signal, so it can tell you that this line is the one connected to that valve. The radar shows a contrast, so it can see things the locator cannot, but the UK Health and Safety Executive’s guidance HSG47 says plainly that radar alone “would not determine the precise nature of the service”.

What each one finds

The table sums up what the two main guidance documents, HSE’s HSG47 (2014) and The Survey Association’s client guide to PAS 128 (May 2025), say about common buried services. “Often” means it depends on ground, depth and congestion.

Buried service Locator, passive Locator, active (signal generator or sonde) GPR
Power cable carrying current Yes Yes Often
Cable with little or no current (street lights by day, empty premises) No Yes, if the signal can be applied Often
Low-voltage DC cable Often not Yes, may need access to earthing Often
Metal water or gas pipe Sometimes, by re-radiated radio Yes, best with a direct connection Often
Plastic water or gas pipe No Only with a tracer wire, a sonde inside, or markers Often, if it contrasts with the soil
Cable inside a plastic duct No, unless sheathed in metal With a tracer rod in the duct Yes, usually
Fibre laid straight in the ground No No Unlikely
Concrete or clay sewer No With a sonde inside Often, if not too deep
Old trench or backfill No No Yes, often
Two services one above the other Lower one may be missed Better, but still hard A metal upper service hides the lower
Service under reinforced concrete Distorted readings Distorted readings Cannot see beneath the steel
Deep sewer Beyond range Sonde inside only Beyond range

Three notes from HSG47 explain most of the “no” answers. Locators, “with the possible exception of ground-probing radar”, do not detect plastic pipes unless a tracer wire, an inserted transmitter or a marker gives them a signal, and few plastic gas and water pipes have been laid with tracer wires. A tracer wire “may not be continuous” if it was damaged or badly laid. And where two services run close together, a locator may show them as one signal, missing the lower one.

How deep each one sees

Radar depth is set by the ground, not by the machine’s brochure. Radar energy is absorbed by electrically conductive ground. ASTM D6432 lists “high conductivity soils, sediments saturated with salt water or highly conductive fluids, and metal” as environments not suited to the method. The US Environmental Protection Agency goes further: “In environments with surficial layers of saturated clays or saline water, the DOI [depth of investigation] may be limited to centimeter scale”, while in dry sand and gravel it cites depths of up to 50 m. Between those extremes sits most real ground.

Frequency is the other control. The EPA notes a trade-off between resolution, which improves with higher frequency, and depth, which improves with lower frequency. A high-frequency antenna that shows a small pipe clearly near the surface will not see a deep sewer; a low-frequency one that reaches the sewer may miss the small pipe. Good surveys use the right antenna for the targets expected, and some use more than one.

For a site in Pakistan this has practical meaning. Land that has just been irrigated or flooded, ground after monsoon rain, saline patches and clay soils all reduce radar depth, sometimes sharply. The same site may give a useful radar picture in a dry month and very little after rain. A survey report should say how deep the radar actually reached in each part of the site, not how deep the equipment can reach in ideal ground.

Locator depth works differently. The receiver estimates depth from the shape of the magnetic field, which works when the field is clean and symmetrical. The Survey Association’s guide warns that nearby utilities and cables distort the field and lead to “unreliable depth measurements”. In a narrow lane where water, gas, power and telecom lines run side by side, locator depths need checking.

How accurate is GPR, and how accurate is the locator?

Across the ground, both instruments can place a line well when conditions are good. Depth is the weak point for both.

GPR does not measure depth directly. It measures the time an echo takes to come back, and converts that time to depth using the speed of the radar wave in the soil. That speed changes with moisture and soil type. If the surveyor assumes the wrong speed, every depth on the site is out in the same direction. A careful surveyor calibrates the speed on site, from a known target or a trial hole, and states how.

A locator’s depth depends on a clean field, as above, and on the signal being on the right line. When a signal bleeds onto a neighbouring pipe, the locator follows the wrong service with confidence.

PAS 128, the UK specification, turns this into a grade for each detected line, with stated position and depth tolerances, and grades a line found by the locator alone and not confirmed by radar no better than QL-B3. Rather than repeat those figures here, our guide to utility survey quality levels sets out the tolerance for each level and what it means for a pipe at 1.5 m depth.

Choose by the question you are asking

“GPR or locator?” is the wrong starting point. Start with the question the survey must answer, and the instruments follow.

Your question What answers it Why
Is there a live cable where we are about to dig? Locator, passive and active, then hand-dug trial hole Live cables give a signal; a genny finds the quiet ones
Where does the plastic water main run? GPR, the owner’s record, and a tracer wire or sonde if one exists Plastic gives the locator nothing to follow
Is the ground clear for a borehole or test pit? Both, at a close grid around the point, then hand-dig the start A drill meets the ground blind
What is under this slab or floor? High-frequency GPR, knowing it cannot see beneath the steel Reinforcement blocks radar and distorts the locator
Map everything along a road we will widen Both, on a planned grid, with chambers lifted and records compared Each instrument covers the other’s blind spots
Exactly how deep is the gas main at the crossing? Trial hole Neither instrument proves depth; exposure does
Is this the line that feeds that building? Locator with the signal applied at a known point Only a signal can link a line to its source

The pattern is consistent with every standard we have read: detection narrows the search; a trial hole confirms. HSG47 puts it simply: “Use trial holes to positively identify a service and its depth.”

What a good detection report says about the instruments

A detection survey report should let a reader judge how much to trust each line. Beyond the utility plan itself, ask for:

  1. The methods used in each area: passive locator, active locator with how the signal was applied, GPR, and any sonde or tracer work.
  2. The radar frequency or frequencies, and whether the data was reviewed in the office (post-processed) or only on screen in the field.
  3. How deep the radar reached in each part of the site, and the ground and weather conditions on the day.
  4. How GPR depths were calibrated: the wave speed used and where it was checked.
  5. Areas where neither instrument could see: under slabs, beside steel fences, in waterlogged ground, beyond depth.
  6. Records that were not confirmed: lines shown by the owners’ records that the instruments did not find.
  7. Ground marks: how lines were marked on site, and in what coordinates the plan is drawn, ideally the same as the topographic survey (see our guide to UTM zones and coordinate systems in Pakistan).

A report that lists every line with equal confidence and has no “not found” or “not surveyed” section has hidden the limits rather than removed them.

Red flags in a “GPR survey” quote

Some quotes sell radar as a complete answer. Watch for these:

  • Radar only, no locator. Live and dead cables, and the link from a line to its source, need the locator. PAS 128 requires both for a detection survey.
  • Locator only, no radar. Plastic pipes, ducts and old trenches go unseen.
  • “All services located” or “100% detection”. The Survey Association’s guide says a well designed survey should detect around 80% to 95% of utilities and that 100% may not be possible.
  • Depths with no method. Every depth should say whether it came from radar (with its calibration), the locator, or a trial hole.
  • No trial holes anywhere on a job where excavation will run close to a main.
  • No statement of ground conditions or achieved radar depth.

In Pakistan there is no national standard to point to, and we know of no call-before-you-dig service, so the brief has to carry these requirements; where records come from here is covered in our guide’s section on where QL-D comes from in Pakistan. Our underground utility survey combines records, surveyed surface features, electromagnetic location, ground penetrating radar and trial holes, and states on the plan how each line was found and where neither instrument could see. To scope a survey, send the site location, a plan of where you will dig or design, and any records you hold through our contact page.

Want RN Tech Associates to handle this for your site?

Send the location and what the work is for. We reply with the questions that decide scope and price.

Questions

Common questions

01What is a GPR survey?

A ground penetrating radar (GPR) survey moves a radar antenna over the ground in lines or a grid and records reflections from buried objects and changes in the soil. Pipes and cables show as curved echoes that a trained operator joins into lines. It finds metal and non-metal targets, but the result is an interpretation, not an identification.

02How accurate is GPR?

Its position across the ground is usually better than its depth. Depth is worked out from the echo's travel time and an assumed speed of the radar wave in that soil, so it is only as good as that speed, which changes with moisture. PAS 128 grades detected lines by tolerance; the figures are in our quality levels guide.

03Can GPR detect plastic pipes?

Often, if the pipe contrasts with the soil around it and the ground lets the radar through. Small plastic pipes, pipes in wet or salty clay, and pipes beneath reinforced concrete may not show. An electromagnetic locator will not see a plastic pipe at all unless a tracer wire or a sonde inside it gives it a signal.

04How deep can ground penetrating radar see?

It depends mostly on how conductive the ground is. ASTM D6432 lists high conductivity soils, sediments saturated with salt water, and metal as environments not suited to radar; the US EPA says depth may be limited to centimetres in saturated clay or saline water and has reached tens of metres in dry sand and gravel. Lower radar frequencies reach deeper but show less detail.

05What is the difference between a CAT and a genny?

A CAT (cable avoidance tool) is the common name for a hand-held electromagnetic receiver. On its own it picks up signals already on a line: power current or re-radiated radio signals. A genny is a signal generator that puts a known signal onto a pipe or cable, so the receiver can trace lines that carry no signal of their own.

06Do I need both GPR and a cable locator?

For almost any survey that will be used to design or dig, yes. Each covers the other's blind spots, and the UK specification PAS 128 requires both for a detection survey. Then dig trial holes where the work comes close to a detected service.

→Request a survey